5-Axis Dry Dental Milling Machine

Five-axis dry dental milling system with tool magazine, disc and block fixtures, and CAD/CAM configuration guidance for dental laboratories.

Ergonomic Design
Medical-Grade Color LCD Display
Durable and Easy-to-Clean

Dental Milling Machine

5-Axis Dry Dental Milling Machine

An enclosed five-axis dry milling system for dental CAD/CAM production planning. Review its tool magazine, disc and block fixtures, chamber features and technical requirements before selecting a laboratory configuration.

  • Machining: five-axis simultaneous dry machining stated in supplied specifications.
  • Tooling: eleven-position magazine and automatic calibration described.
  • Material planning: zirconia, wax, PMMA, PEEK and composite resin listed in the parameter sheet.
  • Chamber: LED illumination and smart progress light bar described.

Request Milling Configuration & Pricing

Configuration scope: This page is based on the supplied product images and parameter sheet. Confirm the exact model, CAM package, tooling, material approvals, extraction and site requirements in the written quotation. Numerical values below are supplier-stated, not independently tested results.

Five-axis dry machining and tooling

The supplied parameter sheet describes simultaneous five-axis dry machining. The enclosure images show a spindle, material holder and numbered tool magazine. The product material also describes automatic calibration and an eleven-tool magazine. Ask which tool positions, tool shanks, calibration routines and replacement parts are supported by the quoted configuration.

The artwork calls the unit all-electric with an airless spindle. Confirm the complete machine utility schedule, including whether any cleaning or accessory function needs compressed air. A spindle description alone does not define all site requirements.

Match materials to fixtures and CAM strategies

The parameter sheet lists zirconia, wax, PMMA, PEEK and composite resin. The material artwork additionally shows a cobalt-chromium sintering blank. Request specific written approval for each blank type and processing state before ordering, especially for materials not included in the main parameter list. Do not assume that the machine can process fully sintered metal or arbitrary dental materials.

For each proposed material, confirm blank dimensions, holder type, tool set, CAM strategy, postprocessor and subsequent processing steps. Disc and block capacity should be checked against the actual fixture supplied with the order.

Machine and process detail images

Five-axis all-electric dry dental milling machine overview
All-electric five-axis dry milling configuration shown; confirm site requirements.
Automatic calibration and eleven-tool magazine presentation
Eleven-position tool magazine and automatic calibration described in supplied material.
Dental milling spindle and angled disc machining illustration
Angled disc machining illustration; request validated accuracy and tool specifications.
Ionizer chamber-cleaning comparison supplied with milling machine
Supplier ionizer comparison; confirm the installed cleaning and extraction system.
Dental milling material examples for blocks and discs
Material examples; approval depends on blank, holder, tool and CAM strategy.
Restoration types illustrated for dental CAD CAM planning
Illustrated restoration applications; confirm the intended material and validated workflow.
Dry milling machine enclosure and reference dimensions
Reference drawing has differing depth callouts; obtain the final installation drawing.
Supplier-stated dry dental milling technical parameters
Supplier-stated technical parameters; confirm the ordered machine revision.

Supplier-stated technical data

ItemSupplied parameter sheetConfirmation before ordering
Machining method5-axis simultaneous, dry machiningModel revision and supported CAM workflows
MaterialsZirconia, wax, PMMA, PEEK, composite resinApproved brands, processing state, fixtures and tools
Disc capacityHeight 10–30mm; diameter 98.5mm maximumHolder and blank interface for selected material
Block capacity40 × 20 × 20mm maximumBlock adapter and usable machining envelope
Rotary axesA axis +32°; B axis 360°Full travel limits and machine-coordinate definition
Tool magazine11 positions described in product materialIncluded tools, shank sizes and tool-change routines
Work chamberLED illumination; smart light bar progress displayInstalled chamber, cleaning and extraction configuration
Power consumption500WInput voltage, frequency, peak load and circuit requirements
Net weight90kgBench load rating, handling and packed shipping weight

Installation space, extraction and service access

The supplied drawing labels a width of 442mm and height of 625mm, with depth-related callouts of both 460mm and 680mm. Obtain the final dimensioned installation drawing before ordering a bench or arranging room access. Confirm enclosure clearance, door opening, extraction hoses, cable routing and service-panel access.

The chamber artwork describes an ionizer intended to assist debris management. Ask for the extraction interface, approved dust collector, filter specification, cleaning procedure and maintenance intervals. The illustration does not replace a material-specific dust-management assessment or the machine instructions.

Plan the digital production package

Request the supported file formats, nesting software, CAM license terms, postprocessor, computer requirements and training scope. Ask for sample machining using your intended material and design, with an agreed acceptance method and documented tool settings. Confirm what is included in the base machine price and what is quoted separately.

RIXI Medical is a dental equipment manufacturer and supplier based in Foshan, China. For a wider digital workflow, review the intraoral scanner category and confirm file compatibility across capture, design and manufacturing. Browse dental equipment for related procurement needs.

Buyer questions

Is this a dry or wet milling machine?

The supplied parameter sheet specifies dry machining. Confirm the approved material and cleaning workflow for the exact configuration.

Does the machine need a compressor?

The sales material describes an airless spindle. Ask for a complete utility schedule to confirm whether other machine or accessory functions need compressed air.

Is CAM software included?

The images show a computer-based workflow but do not define the license package. Confirm software, postprocessor, updates, computer and training in the quotation.

Can it mill every material shown in the images?

Material eligibility depends on the specific blank, processing state, fixture, tools and CAM strategy. Request written material approval and sample acceptance for the intended workflow.

Request the five-axis dry milling package

Share your materials, restoration types, expected workload, existing CAD/CAM software and destination market through the RIXI Medical product enquiry page. Request the current datasheet, final installation drawing and itemized supply scope.

Need Dental Equipment Pricing or Configuration Details?

Contact RIXI Medical for model comparison, distributor pricing, packaging information, OEM/ODM requirements and after-sales support.

Request Product Information

More Model Options

Get Free Quote